UB Series · High Frequency

EX-UB

Online Double-Conversion UPS
EX-UB UPS

IGBT-based double conversion at 91% efficiency and 0.99 power factor — built for servers, networking, medical, and lab equipment that can't afford downtime.

1–3 kVA 1Φ–1Φ IGBT² Technology Double Conversion

Ideal for servers & networking equipment, digital printers, medical equipment, and laboratory equipment.

EX-UB UPS
0 kVA
Max Capacity
0%
Efficiency
0ms
Transfer Time
0
Input Power Factor
Why EX-UB

Built around what actually matters

Output Waveform · 50Hz
Utility Mains · 50Hz
EX-UB Output · 50Hz
THD < 2% (linear load) · output tracks the ideal sine so closely the two lines nearly overlap

High-Frequency Double Conversion

IGBT technology on both the inverter and rectifier stages, with fully digitized microprocessor control, keeps output voltage and frequency tightly regulated — so the waveform your equipment sees tracks the ideal utility sine almost exactly.

  • 0ms transfer time (AC to Battery)
  • THD < 2% on linear load
  • Wide input voltage range, input PF > 0.99
Dimensions (W × D × H)
1 kVA
215mm
2 kVA
339mm
3 kVA
339mm
Height shown · net weight from 14kg (1kVA) to 34kg (3kVA)

Fully Digitized, Simple to Run

Microprocessor-controlled with a clear LCD display for input/output voltage, frequency, load, and operating mode — plus cold-start capability and advanced battery charging even when the UPS itself is off.

  • LCD display & multi-colour LED status
  • Cold start & battery charging in OFF mode
  • RS232 standard, optional SNMP card
Efficiency
91%
Efficiency
>110% load, 30s to bypass
>150% load, 300ms to bypass
Short-circuit & EMI/RFI filtered

Full Protection, By Design

Short-circuit and overload protection, an EMI/RFI noise filter, and graceful bypass behaviour under sustained overload keep EX-UB — and everything connected to it — running safely.

  • Short-circuit & overload protection
  • EMI/RFI noise filter
  • Smart RS232 monitoring, optional SNMP

Full Specifications

EX-UB · HF1101 / HF1102 / HF1103 · 1–3 kVA · Single Phase In – Single Phase Out

ParameterSpecification
Capacity (VA)1000 / 2000 / 3000 VA
Nominal Input Voltage220 / 230 / 240 VAC
Operating Voltage Range110–300 VAC (50% load), 160–280 VAC (100% load)
Operating Frequency Range46–54Hz or 56–64Hz ± 0.5Hz (auto-sensing)
Input Power Factor> 0.99
Output Voltage / Power Factor220 / 230 / 240 VAC ± 1% / 0.9 Std.
Output FrequencySynced to utility on AC mode; 50/60Hz ± 0.2% on battery
Harmonic Distortion (THDv)< 2% (linear load), < 5% (non-linear load)
Crest Factor3:1 (max)
Efficiency> 91%
Battery DC Voltage36Vdc (1kVA), 96Vdc (2–3kVA)
Battery Type12V / 7Ah × 3 (1kVA), 12V / 7Ah × 8 (2–3kVA)
Backup Time (Full Load)5–8 minutes, model dependent
Typical Recharge Time8 hours (to 90% capacity)
Overload Capability>110% for 30s, >150% for 300ms — then bypass
Transfer Time0ms (AC–Battery), ~2.5ms typical (AC–Bypass)
Communication InterfaceRS232 standard, SNMP card optional
Operating Temperature0°C to 40°C
Storage Temperature-25°C to 55°C
Humidity0–95% (non-condensing)
Noise Level< 45dB
Safety StandardIEC / EN62040-1, IEC / EN60950-1